Platinum-Iridium alloy is considered by many to be the “gold standard” for chronic recording and microstimulation due to its excellent electrochemical and mechanical characteristics.
Advantages | Disadvantages |
|
|
These monopolar microelectrodes of MicroProbes are also available in Tungsten, Elgiloy (an alloy similar to stainless steel), and Pure Iridium metal. As an alternative we provide them with a thin coat of vapor-deposited Parylene-C insulation instead of the Polymide tubing. Each electrode is etched to a fine taper and tipped using a proprietary process to a specific impedance value. Four different tip profiles are also available to further fine-tune your electrode selection to your particular application.
We offer a variety of different tip alternatives for those that prefer a specialized electrode profile for their research.
The tip selection can provide subtle yet important changes to the performance of the electrode, as described below. It is recommended that first time users consider experimenting with different tip profiles to determine which works best for their recording or stimulation protocols.
For some applications concentric or bipolar electrodes (stereotrodes) are useful.
Monopolar Electrodes, Platinum-Iridium, Heat Treated Tapered Tip
(75 µm × 2")
With Polymide Tubing
Item |
Length |
Shaft Diameter |
Tip Diameter |
Impedance |
Applications |
Pkg of 10 |
PI2PT30.01H3 |
51 mm |
0.126 mm |
1-2 µm |
0.01 MΩ |
MultiUnit & ERP recording & Stim |
|
PI2PT30.05H3 |
51 mm |
0.126 mm |
0.05 MΩ |
|||
PI2PT30.1H3 |
51 mm |
0.126 mm |
0.1 MΩ |
|||
PI2PT30.5H3 |
51 mm |
0.126 mm |
0.5 MΩ |
Single & multiunit rec. & stim. |
||
PI2PT31.0H3 |
51 mm |
0.126 mm |
1 µm |
1.0 MΩ |
||
PI2PT31.5H3 |
51 mm |
0.126 mm |
1.5 MΩ |
|||
PI2PT32.0H3 |
51 mm |
0.126 mm |
2.0 MΩ |
|||
PI2PT32.5H3 |
51 mm |
0.126 mm |
2.5 MΩ |
Greater Selectivity - Small Cells |
||
PI2PT33.0H3 |
51 mm |
0.126 mm |
3.0 MΩ |
|||
PI2PT35.0H3 |
51 mm |
0.126 mm |
5.0 MΩ |
Monopolar Electrodes, Platinum-Iridium, Heat Treated Tapered Tip
(125 µm × 2")
With Polymide Tubing
Item |
Length |
Shaft Diameter |
Tip Diameter |
Impedance |
Applications |
Pkg of 10 |
PI2PT30.01H5 |
51 mm |
0.216 mm |
1-2 µm |
0.01 MΩ |
MultiUnit & ERP recording & Stim |
|
PI2PT30.05H5 |
51 mm |
0.216 mm |
0.05 MΩ |
|||
PI2PT30.1H5 |
51 mm |
0.216 mm |
0.1 MΩ |
|||
PI2PT30.5H5 |
51 mm |
0.216 mm |
0.5 MΩ |
Single & multiunit rec. & stim. |
||
PI2PT31.0H5 |
51 mm |
0.216 mm |
1 µm |
1.0 MΩ |
||
PI2PT31.5H5 |
51 mm |
0.216 mm |
1.5 MΩ |
|||
PI2PT32.0H5 |
51 mm |
0.216 mm |
2.0 MΩ |
|||
PI2PT32.5H5 |
51 mm |
0.216 mm |
2.5 MΩ |
Greater Selectivity - Small Cells |
||
PI2PT33.0H5 |
51 mm |
0.216 mm |
3.0 MΩ |
|||
PI2PT35.0H5 |
51 mm |
0.216 mm |
5.0 MΩ |
Monopolar Electrodes, Platinum-Iridium, Heat Treated Tapered Tip
(125 µm × 3")
With Polymide Tubing
Item |
Length |
Shaft Diameter |
Tip Diameter |
Impedance |
Applications |
Pkg of 10 |
PI3PT30.01H5 |
76 mm |
0.216 mm |
1-2 µm |
0.01 MΩ |
MultiUnit & ERP recording & Stim |
|
PI3PT30.05H5 |
76 mm |
0.216 mm |
0.05 MΩ |
|||
PI3PT30.1H5 |
76 mm |
0.216 mm |
0.1 MΩ |
|||
PI3PT30.5H5 |
76 mm |
0.216 mm |
0.5 MΩ |
Single & multiunit rec. & stim. |
||
PI3PT31.0H5 |
76 mm |
0.216 mm |
1 µm |
1.0 MΩ |
||
PI3PT31.5H5 |
76 mm |
0.216 mm |
1.5 MΩ |
|||
PI3PT32.0H5 |
76 mm |
0.216 mm |
2.0 MΩ |
|||
PI3PT32.5H5 |
76 mm |
0.216 mm |
2.5 MΩ |
Greater Selectivity - Small Cells |
||
PI3PT33.0H5 |
76 mm |
0.216 mm |
3.0 MΩ |
Monopolar Electrodes, Platinum-Iridium, Heat Treated Tapered Tip
(225 µm × 2")
With Polymide Tubing
Item |
Length |
Shaft Diameter |
Tip Diameter |
Impedance |
Applications |
Pkg of 10 |
PI2PT30.01H10 |
51 mm |
0.370 mm |
1-2 µm |
0.01 MΩ |
MultiUnit & ERP recording & Stim |
|
PI2PT30.05H10 |
51 mm |
0.370 mm |
0.05 MΩ |
|||
PI2PT30.1H10 |
51 mm |
0.370 mm |
0.1 MΩ |
|||
PI2PT30.5H10 |
51 mm |
0.370 mm |
0.5 MΩ |
Single & multiunit rec. & stim. |
||
PI2PT31.0H10 |
51 mm |
0.370 mm |
1 µm |
1.0 MΩ |
||
PI2PT31.5H10 |
51 mm |
0.370 mm |
1.5 MΩ |
|||
PI2PT32.0H10 |
51 mm |
0.370 mm |
2.0 MΩ |
|||
PI2PT32.5H10 |
51 mm |
0.370 mm |
2.5 MΩ |
Greater Selectivity - Small Cells |
||
PI2PT33.0H10 |
51 mm |
0.370 mm |
3.0 MΩ |
Common Tip Profiles: